specification:

Accuracy is specified for a period of one year after calibration and at 18°C to 28°C, with relative humidity < 75%.Accuracy specifications take the form of :± ([% of Reading]+[number of Least Significant Digits])

DC Voltage:

  Range

Resolution

Accuracy

200mV

100µV

± (0.5% + 2)

2V

1mV

± (0.8% + 2)

20V

10mV

200V

100mV

1000V

1V

± (1.0% + 2)

 
Input Impedance: About 10M
Overload Protection:
the 200mV range: 250V DC/AC rms
other ranges: 1000V DC or 750V AC rms
 
AC Voltage:
 

Range 

Resolution

 Accuracy

200mV

100µV

± (1.0% + 3)

2V

1mV

20V

10mV

200V

100mV

750V

1V

± (1.5% + 5) 

Input Impedance: About 10M
Frequency Range:
200V and 750V ranges: 40Hz - 100Hz
other ranges: 40Hz - 400Hz
Response: Average, calibrated in rms of sine wave
Overload Protection:
the 200mV range: 250V DC/AC rms
other ranges: 1000V DC or 750V AC rms
 
DC Current:

Range

Resolution

Accuracy

2mA

1µA

± (0.8% + 2)

20mA

10µA

± (1.5% + 2)

200mA

100µA

 

20A

10mA

± (2.0% + 5) 

Overload Protection:
250mA/250V Fast fuse ( for protection for " mA " terminal
inputs only )
( There is no fuse protection for " 20A " terminal inputs. )
Max. Allowable Input Current: 20A
( For inputs > 2A: measurement duration < 10 secs,
interval > 15 minutes )
Max Voltage Drop: 200mV

 

AC Current:

Range

Resolution

Accuracy

2mA

1µA

± (1.2% + 3)

20mA

10µA

± (1.8% + 3)

200mA

100µA

 

20A

10mA  

± (3.0% + 5)  

 
Frequency Range: 40Hz - 400H
Overload Protection:
250mA/250V Fast fuse ( for protection for " mA " terminal
inputs only )
( There is no fuse protection for " 20A " terminal inputs. )
Max. Allowable Input Current: 20A
( For inputs > 2A: measurement duration < 10 secs,
interval > 15 minutes )
Response: Average, calibrated in rms of sine wave
Max Voltage Drop: 200mV

Resistance:

Range

Resolution

Accuracy

200Ω

0.1

± (1.2% + 3)

2kΩ

± (1.0% + 2)

20kΩ

10Ω

 

200kΩ

100Ω

 

20MΩ

10kΩ

± (1.5% + 2)

200MΩ

100kΩ

± [ 5%×(reading - 10) + 10 ] 

Open Circuit Voltage: < 3.2V
Overload Protection: 250V DC/AC rms

Capacitance:

Range

Resolution

Accuracy

2nF

1pF

± (5% + 10)

20nF

10pF

± (5% + 5)

200nF

100pF

2µF

1nF

200µF

0.1µF 

Transistor hFE Test:

Range

hFE

Test Current

Test Voltage

PNP & NPN

0 - 1000

Ib 10µA

Vce 2.8V 

Diode and Continuity:

Range

Description

Test Condition

 

The approx. forwardvoltage drop of thediode is shown on the display.

Open Circuit Voltage:about 2.8V

 

The built-in buzzer will sound if the resistance is less than about 30 . The buzzer may or maynot sound if the resistance is between 30 and 150 . The buzzer will not sound if the resistance is more than 150 .

Open Circuit Voltage: about 2.8V 

 

ALL SUN EM8910 Digital Multimeter Multi Tester Backlight AC/DC Ammeter Voltmeter Ohm Portable Meter Voltage Meter
ALL SUN EM8910 Digital Multimeter Multi Tester Backlight AC/DC Ammeter Voltmeter Ohm Portable Meter Voltage Meter
ALL SUN EM8910 Digital Multimeter Multi Tester Backlight AC/DC Ammeter Voltmeter Ohm Portable Meter Voltage Meter
ALL SUN EM8910 Digital Multimeter Multi Tester Backlight AC/DC Ammeter Voltmeter Ohm Portable Meter Voltage Meter

Payment & Security

Payment methods

PayPal

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.


Security

Estimate shipping

You may also like

Recently viewed