All-Sun EM5510 5 In 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester

Save $20.99
SKU: EM5510

Price:
$58 $78.99

Tax included Shipping calculated at checkout

Stock:
In stock

Description

All-Sun EM5510 5 In 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester

Feature:

> This multimeter is 4000 count, 3 3/4-digit multimeter.

> It can be used to measure DC and AC voltage, DC and AC current,resistance, capacitance, frequency, diode, temperature, continuity,duty cycle and electromagnetic field radiation.

> It can be used as a test tool for environment and devices.

> It is a high-performance and versatile meter.

All-Sun EM5510 5 In 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester
All-Sun EM5510 5 In 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester
All-Sun EM5510 5 In 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester
All-Sun EM5510 5 In 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester
All-Sun EM5510 5 In 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester
All-Sun EM5510 5 In 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester
All-Sun EM5510 5 In 1 Digital Multimeter Sound Level Humidity Luminosity Temperature LCD AC/DC Multimeter Volt Amp Ohm Tester

Safety Information >>>

This meter has been designed according to IEC-61010 concerning electronic measuring

instruments with a measurement category (CAT II 600V) and pollution degree 2.

 

GENERAL SPECIFICATION >>>

> Display: 3 3/4-digit LCD, with a max. reading of 3999  

> Overrange Indication: "OL" shown on the LCD

> Negative Polarity Indiaction: "-" displayed automatically 

> Sampling Rate: 2-3 times/ sec

> Operating Temperature: 0-40 ℃, <75%RH

> Storage Temperature: -30-60 ℃, <85%RH

> Operating Altitude: 0 to 2000 meters

> Power: 9V battery (6F22)  Not Include

> Dimensions (W×L×T): 83×162×47 mm

> Weight: 310g (with battery)

Accuracy is specified for a period of one year after calibration and 

at 18℃ to 28 ℃, with relative humidity <75%. Normally, accuracy

specifications take the form of: ±([% of Reading]+[number of Least

Significant Digits])  

         

DC Voltage >>>

Range

Resolution

Accuracy

400mV

0.1mV

±(1.0%+5)

4V

1mV

 

±(0.8%+3)

40V

10mV

400V

100mV

600V

1V

±(1.0%+5)

Input Impedance: the 400mV range: >1000MΩ

                          the other ranges: 10MΩ

Max.Permitted Input: 400Mv range: 250V DC or AC

                               the other ranges: 600V DC or AC

AC Voltage >>>

Range

Resolution

Accuracy

4V

1mV

 

±(1.0%+5)

 

40V

10mV

400V

100mV

600V

1V

±(1.2%+5)

Input Impedance: 10MΩ

Max.Permitted Input: 600V DC or AC

Frequency Range: 40Hz ~400Hz

Response:Average, calibrated in rms of sine wave

DC Current >>>

Range

Resolution

Accuracy

400uA

0.1uA

 

 

±(1.2%+3)

 

4000 uA

1 uA

40mA

10 uA

400mA

100 uA

4A

1mA

±(1.8%+3)

10A

10mA

±(2.0%+5)

Overload Protection:

For "MA℃” jack inputs: Fuse, 500Ma/ 250V, fast action

For "10A" jack inputs: no fuse

Max. Input Current: 10A (For inputs>5A: 

                                       measurement duration<10 secs,

                                       interval>15minutes)

Max. Voltage Drop: 400mV

AC Current >>>

Range

Resolution

Accuracy

400uA

0.1uA

 

 

±(1.5%+5)

 

4000 uA

1 uA

40mA

10 uA

400mA

100 uA

4A

1mA

±(2.0%+5)

10A

10mA

±(2.5%+5)

Overload Protection:

For "MA℃” jack inputs: Fuse, 500Ma/ 250V, fast action

For "10A" jack inputs: no fuse

Max. Input Current: 10A (For inputs>5A: 

                                      measurement duration<10secs,

                                      interval>15minutes)

Max. Voltage Drop: 400mV

Frequency Range: 40Hz~400Hz

Response: Average, calibrated in rms of sine wave

RESISTANCE >>>

Range

Resolution

Accuracy

400Ω

0.1Ω

±(1.0%+5)

4kΩ

 

 

±(1.0%+3)

 

40 kΩ

10Ω

400 kΩ

100Ω

4MΩ

1kΩ

40MΩ

10kΩ

±(2.0%+5)

Overload Protection: 250V DC/ AC

Open Circuit Voltage: about 0.25V

FREQUENCY >>>

Range

Resolution

Accuracy

10Hz

0.01Hz

±(1.0%+3)

100Hz

0.1Hz

 

±(0.8%+3)

1kHz

1 Hz

10kHz

10 Hz

100kHz

100 Hz

±(1.0%+3)

200kHz

1kHz

>200kHz

 

Not specified

Input voltage: 1 Vrms~20 Vrms

Overload Protection: 250VDC/AC

CAPACITANCE(use Relative mode) >>>

Range

Resolution

Accuracy

4nF

0.001nF

 

 

±(4.0%+5)

40nF

0.01nF

400nF

0.1nF

4uF

1nF

40uF

10nF

100uF

100nF

±(8.0%+5)

Overload Protection: 250V DC/ AC

TEMPERATURE >>>

Range

Resolution

Accuracy

-20℃~400℃

0.01℃

±1.5%±3℃

400℃~1000℃

1℃

±2.0%±3℃

Overload Protection: Fuse, 500Ma/250V, fast action

DUTY CYCLE >>>

Range

Resolution

Accuracy

1%~99%

0.1%

1Hz~10kHz:±(2.0%+5)

>10kHz: not specified

Input Voltage: 3Vp-p~10Vp-p

Overload Protection: 250V DC/AC

HUMIDITY(%RH) >>>

Range

Resolution

Accuracy

30%~90%

0.1%

---------------------

Working Temperature: 0~40 ℃

Response Time: 45% RH→90%RH less than or equal to 10minutes

                          90% RH→45%RH less than or equal to 15minutes

SOUND LEVEL(dB) >>>

Range

Resolution

Accuracy

35~100dB

0.1dB

---------------------------------

Frequency: 100~10000Hz

INTENSITY OF ILLUMINATION(Lux) >>>

Range

Resolution

Accuracy

400x10 Lux

1 Lux

---------------------------------

4000x10 Lux

10Lux

 

ACCESSORIES >>>

Test Lead; Temperature probe; Battery; Users Manual; Holster

Payment & Security

Payment methods

PayPal

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.


Security

Estimate shipping

You may also like