Description
FEATURE >>>
1) High-performance
2) Display: 3 3/4-backlight LCD display, max.reading of 3999
3) Data-hold mode
4) Auto polarity indication
5) Manual range and autorange mode
6) Auto/manual power-off
7) Relative mode
8) Overload protection: "OL" shown on the LCD
9) Low battery indication
SPECIFICATION >>>
> Negative Polarity Indiaction: "-" displayed automatically
> Sampling Rate: 2-3 times/sec
> Operating Temperature: 0-40 degree C,<75%RH
> Storage Temperature: -30-60 degree C,<85%RH
> Operating Altitude: 0 to 2000 meters
> Battery: 9V,6F22 or equivalent
> Dimensions: 162x83x47mm
> Weight: about 310g (including battery and the holster)
Technical Specifications >>>
Accuracy is specified for a period of one year after calibration
and at 18 ℃ to 28 ℃, with relative humidity <75%. Normally,
accuracy specifications take the form of: ±([% of Reading]+
[number of Least Significant Digits])
ACCESSORIES >>>
Test Lead; Temperature probe; Battery; Users Manual; Holster
DC Voltage:
Range |
Resolution |
Accuracy |
400mV |
0.1mV |
±(1.0%+5) |
4V |
1mV |
±(0.8%+3) |
40V |
10mV |
|
400V |
100mV |
|
600V |
1V |
±(1.0%+5) |
Input Impedance:the 400mV range:>1000MΩ
the other ranges:10MΩ
Max.Permitted Input:250V DC or AC
AC Voltage >>>
Range |
Resolution |
Accuracy |
4V |
1mV |
±(1.0%+5)
|
40V |
10mV |
|
400V |
100mV |
|
600V |
1V |
±(1.2%+5) |
Input Impedance: 10MΩ
Max.Permitted Input:250V DC or AC
Frequency Range:40Hz ~400Hz
Response:Average,calibrated in rms of sine wave.
DC Current >>>
Range |
Resolution |
Accuracy |
400 uA |
0.1 uA |
±(1.2%+3)
|
4000 uA |
1 uA |
|
40 mA |
10 uA |
|
400 mA |
100 uA |
|
4 A |
1 mA |
±(1.8%+3) |
10 A |
10 mA |
±(2.0%+5) |
Overload Protection:
For”mA”jack inputs:Fuse,500Ma/250V,fast action,
For”10A”jack inputs:Fuse,10A/250V,fast action
Max.Input Current:10A(For inputs>5A:
measurement duration<10secs,interval>15minutes)
Max.Voltage Drop:400Mv
AC Current >>>
Range |
Resolution |
Accuracy |
400uA |
0.1uA |
±(1.2%+3)
|
4000 uA |
1 uA |
|
40mA |
10 uA |
|
400mA |
100 uA |
|
4A |
1mA |
±(1.8%+3) |
10A |
10mA |
±(2.0%+5) |
Overload Protection:
For "mA degree C" jack inputs: Fuse, 500Ma/250V, fast action
For "10A" jack inputs: Fuse, 10A/250V, fast action
Max. Input Current: 10A(For inputs>5A: measurement duration <10secs, interval >15minutes)
Max. Voltage Drop: 400MV
Frequency Range: 40Hz~400Hz
Response: Average, calibrated in rms of sine wave.
RESISTANCE >>>
Range |
Resolution |
Accuracy |
400 Ω |
0.1 Ω |
±(1.0%+5) |
4 kΩ |
1 Ω |
±(1.0%+3)
|
40 kΩ |
10 Ω |
|
400 kΩ |
100Ω |
|
4 MΩ |
1 kΩ |
|
40 MΩ |
10 kΩ |
±(2.0%+5) |
Overload Protection: 250V DC/AC
Open Circuit Voltage: about 0.25V
FREQUENCY
Range |
Resolution |
Accuracy |
10Hz |
0.01Hz |
±(1.0%+3) |
100Hz |
0.1Hz |
±(0.8%+3) |
1kHz |
1 Hz |
|
10kHz |
10 Hz |
|
100kHz |
100 Hz |
±(1.0%+3) |
200kHz |
1kHz |
|
>200kHz |
|
Not specified |
Input voltage:1 Vrms~20 Vrms
Overload Protection:250VDC/AC
CAPACITANCE(use Relative mode) >>>
Range |
Resolution |
Accuracy |
4 nF |
0.001nF |
±(4.0%+5) |
40 nF |
0.01 nF |
|
400 nF |
0.1 nF |
|
4 uF |
1 nF |
|
40 uF |
10 nF |
|
100 uF |
100 nF |
±(8.0%+5) |
Overload Protection: 250V DC/AC
TEMPERATURE >>>
Range |
Resolution |
Accuracy |
-20℃~400℃ |
0.01℃ |
±1.5% ±3℃ |
400℃~1000℃ |
1℃ |
±2.0% ±3℃ |
Overload Protection: Fuse, 500Ma/250V, fast action
DUTY CYCLE >>>
Range |
Resolution |
Accuracy |
5%~95% |
0.1% |
1Hz~10kHz:±(2.0%+5) |
>10kHz: not specified |
Input Voltage: 3Vp-p~10Vp-p
Overload Protection: 250V DC/AC
ELECTROMAGNETIC RADIATION >>>
Range |
Resolution |
Accuracy |
400mG |
0.1mG |
1Hz~10kHz:±(2.0%+5) |
4000mG |
1mG |
±(5%+3) at 50Hz/60Hz |
Frequency Scope:40~400Hz(Single axis measurements only)
1 Tesla=1000Gauss; 1Gauss=1000 Milligauss
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.