Description
Features:
Specifications:
Connector type :
|
2 channels with BNC sockets, 20 mm spacing.
|
|
Vertical resolution:
|
8 Bit ~ 13 Bit .
|
|
Maximum sampling rate (S/s):
|
250M (real time), 1G (equivalent)
|
|
Bandwidth ( −3 dB):
|
100MHz
|
|
Input coupling:
|
AC/DC.
|
|
Input characteristics:
|
1MΩ || 25pF.
|
|
PC OS requirements:
|
Windows XP, Win 7, Win 8.1, Win10 (32 bit and 64 bit).
|
|
Over-voltage protection:
|
±60.0v (x1), ±600.0v (x10). (DC + AC peak)
|
|
Triggering type:
|
Rising/falling edge according to trigger level, Pulse width trigger.
|
|
Triggering mode:
|
None, auto, normal, single.
|
|
Pre-trigger capture:
|
1%~99% of capture size.
|
|
Automatic measurements: |
Maximum, minimum, average, RMS, frequency, period, positive pulse width, negative pulse width, duty cycle, rise time, peak-to-peak value.
|
|
Frequency response mapping |
Scanning the frequency, record the process frequency and magnification data, and draw the frequency response curve.
|
|
Measurement statistical curve:
|
The historical trend of the automatically measured quantities can be plotted for statistics and analysis.
|
|
Pass / Fail detection: |
You can set the upper and lower limits of the measurement quantity, and perform Pass / Fail detection and fault alarm function on the measured signal. |
|
Deep measurement:
|
With this function, the waveform jump points are automatically numbered and marked, and the time difference between the two adjacent numbers is automatically displayed. |
|
Samples Interpolation:
|
Linear or sin(x)/x.
|
|
FFT:
|
1024 ~ 16K points.
|
|
FFT window function:
|
Rectangle, Hanning, Hamming, Blackman.
|
|
Math:
|
A+B, A-B, AxB, X-Y.
|
|
Acquisition Modes:
|
Normal mode / High Resolution mode / Peak detect mode.
|
|
Waveform recording and playback: |
File format :
|
*.oscxxx.
|
Record depth:
|
50 ~ 450 frames.
|
|
File size:
|
6 MB ~ 20GB.
|
|
Save as file:
|
txt, csv, excel, oscxxx, jpg.
|
|
Comparison reference:
|
Support waveform image import and real-time waveform comparison reference. It can import waveform pictures, set gray level and transparency, move up and down, and zoom in and out horizontally and longitudinally.
|
|
Data logger Sampling Interval:
|
1 second to 1 hour.
|
|
Data logger Record Duration:
|
1 minute ~ 72 hours.
|
|
Temperature range:
|
Operating: 0 °C to 40 °C (20 °C to 30 °C for stated accuracy). Storage: −20 °C to +60 °C.
|
|
Reference Output:
|
1K Hz, 1.5 V square wave output with 50% duty cycle. Software-configurable PWM output with adjustable frequency and duty cycle.
|
|
Size:
|
153(L) x 93(W) x 23(H) mm. |
|
Languages (full support):
|
English, Chinese (simplified). |
|
Compliance: |
CE, FCC.
|
Net weight:
|
210 g.
|
||
Input sensitivity (10 vertical divisions): |
20 mV/div to 2 V/div.
|
||
Input ranges( probe x1):
|
±100 mV to ±5 V full scale, in 7 ranges.
|
||
Timebase selection (10 horizontal divisions):
|
5 ns/div ~ 60 s/div, in 32 ranges.
|
||
Typical noise (peak to peak voltage):
|
20 mV/div
|
2 mV
|
|
50 mV/div
|
5.8 mV
|
||
100 mV/div
|
8 mV
|
||
200 mV/div
|
22 mV
|
||
500 mV/div
|
38.8 mV
|
||
1 V/div
|
88.2 mV
|
||
Memory depth
(byte /Ch):
|
64K
|
≤50 ms/div
|
|
258K
|
200 ms/div
|
||
645K
|
500 ms/div
|
||
2M
|
1 s/div
|
||
8M
|
2 s/div
|
||
10M
|
10 s/div
|
||
20M
|
20 s/div
|
||
30M
|
30 s/div
|
||
40M
|
40 s/div
|
||
50M
|
50 s/div
|
||
60M
|
60 s/div
|
||
Trigger type:
|
Hardware
|
||
Trigger source:
|
Channel A
|
||
Power consumption:
|
5 v || (248~279) mA
|
||
Protocols decoding:
|
UART/RS-232/485/422, I²C,CAN,SPI
|
||
FIR Filtering:
|
Band-pass, Band-stop
|
||
Custom probes
|
Support two-point calibration of any current clamp on the market. |
Model:
|
OSCH02 |
Detail:
|
Support Windows |
Input channels:
|
2
|
Maximum sampling rate (S/s):
|
1G
|
Bandwidth (−3 dB):
|
100MHz
|
FFT:
|
√ |
Data logger:
|
√ |
I/O extension:
|
× |
Serial bus decoding:
|
√ |
Hardware trigger:
|
√ |
Pulse width triggersupport:
|
√ |
Signal generator module support:
|
× |
Logic analyzer module :
|
× |
Android Phone/ Tablet support
|
× |
Isolated differential input model
|
Optional |
Custom probes
|
√ |
Frequency response mapping
|
√ |
Payment & Security