Description
All-Sun EM1230 2in1 Handheld Oscilloscope 2 Channels with Color Screen Scope Digital Multimeter DMM Meter
25MHz Dual/ Two Channel Waveform Real Time Sample Rate
100MSa/s LCD Backlight EM1230
Feature:
1. This handheld oscilloscope is a portable waveform measurement tool. And one of best 2 in 1 test tools in outdoor testing, repairing or teaching.
2. When the real time sample rate is 100MSa/s, the bandwidth is 25MHz. When the real time sample rate is 500MSa/s, the bandwidth is 60MHz.When the real time sample rate is 1GSa/s, the bandwidth is 100MHz.
(Notice, if you want to test the rate higher than 100MSa/s, you should purchase additional probe)
3. Its multimeter part uses a dedicated chip (6000-count), which can provide a higher precision.
4. The large capacity lithium battery can ensure at least 6 hours working after fully charged.
Bandwidth |
DC - 25MHz ( -3dB ) |
Channel Number |
2 |
Raise Time |
14ns |
Sampling Rate |
100MSa/s |
Horizontal Sensitivity |
10ns/div - 5s/div |
Horizontal Precision |
0.01% + 1 pixel |
Vertical Sensitivity |
10mV/div - 500V/div |
Vertical Precision |
±(3% + 1 pixel) |
Vertical Resolution |
8 bit |
Maximum Allowable Input Voltage |
CAT II 300V |
Coupling |
AC, DC |
Input Impedance |
1MΩ, ≤20pF |
Trigger Source |
CHA, CHB, external trigger |
Trigger Mode |
Normal, Auto, Single |
Trigger Sensitivity |
≤1.0 div |
Trigger Slope |
rising or falling edge of waveform |
Trigger Coupling |
AC, DC |
Display |
6000 counts |
Max. Allo wable Input Voltage |
CAT III 600V |
Cursor Measurement |
time and voltage measurements |
Display |
3.5″ TFT LCD, 52mm×70mm, 240 ×320 pixels |
Memory Location locations |
10 waveform storage locations and 10 setup storage |
Battery |
3.7V lithium battery |
Power Adapter |
Output: DC 5V/8W |
Operating Environment |
Temperature: 0°C ~ 40°C |
Relative Humidity: ≤ 75% |
|
Storage Environment |
Temperature: -10°C ~ 50°C |
Relative Humidity: ≤ 85% |
|
Operating Altitude |
0 ~ 2000m |
Dimensions |
212mm × 121mm × 50mm ( for main body only ) |
Weight |
About 700g |
Function |
Range |
Accuracy |
|||
DC Voltage |
600mV/6V/60V/600V/1000V |
±(1% + 5 counts ) |
|||
AC Voltage |
600mV/ 6V/ 60V/ 600V/1000V |
±(1.2% + 5 counts ) |
|||
DC Current accuracy |
See the user manual of the current probe. |
same as DCV ( add current probe |
|||
AC Current during |
See the user manual of the current probe. |
If the current probe’s output voltage measurement is DC voltage,measurem accuracy is DCV measuremen plus current probe accuracy. |
|||
|
600Ω/6kΩ/60kΩ/600kΩ/6MΩ |
±(1.2% + 5 counts ) |
|||
60MΩ |
±(2% + 5 counts ) |
||||
Capacitance |
6nF\600nF\6μF\60μF\600μF\6nF\6mF |
±(4% + 5 counts ) |
|||
Diode Test |
Test voltage is about 3V. |
±(5% + 10 counts ) |
Continuity Test If the resistance is less than about 5Ω, the built-in buzzer will sound.
Payment & Security
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.